e-ISSN: Pending
Negative / Null Result ReportOpen accessScience

Estimating the whole-body effective dose and health risks as well as introducing a new easy method for eye lens dosimetry in interventional cardiology procedures

Alireza Hatami; Mahmoud Bagheri; Farzaneh Falahati; Amin Banaei; Razzagh Abedi-Firouzjah; Hamed Zamani; Mohammad Kiapour; Farideh Momeni · 2020 · MethodsX

WASTE classifies this as Negative / Null Result Report · AI classification, approximate

The study found no significant effect — useful as a negative control or null benchmark for your own design.

Abstract

This study aimed to introduce a new method for eye lens thermo-luminescent dosimetry and also estimate the dose associated with induced cancer risk due to the ionizing radiation exposure received by physicians and other staff cooperating in interventional cardiology (IC) procedures. The measurements were performed with six TLDs (thermoluminescent dosimeters): four TLDs for eye lens dosimetry (2 positioned on respiratory/surgical mask under the eye region as the new method; and 2 near the outside border of the eye as the common method) and two TLDs for whole-body dosimetry. Whole-body doses wer

Abstract by Alireza Hatami; Mahmoud Bagheri; Farzaneh Falahati; Amin Banaei; Razzagh Abedi-Firouzjah; Hamed Zamani; Mohammad Kiapour; Farideh Momeni, MethodsX (2020) — licensed CC BY 4.0.

About to run something similar?

Run an AI Precheck on your own design to catch failure modes like this one before you spend the time. Your first desk check is free.

WASTE indexes this work — it does not host or republish it. Failure-type classification is automated and approximate.

Metadata source: DOAJ · DOI 10.1016/j.mex.2020.101097