Ground test results of the electromagnetic interference for the x-ray microcalorimeter onboard XRISM

Miki Kurihara; Masahiro Tsujimoto; Megan E. Eckart; Caroline A. Kilbourne; Frederick T. Matsuda; Brian McLaughlin; Shugo Oguri; Frederick S. Porter · 2023 · arXiv

WASTE classifies this as Negative / Null Result Report · AI classification, approximate

The study found no significant effect — useful as a negative control or null benchmark for your own design.

Abstract (excerpt)

Electromagnetic interference (EMI) for low-temperature detectors is a serious concern in many missions. We investigate the EMI caused by the spacecraft components to the x-ray microcalorimeter of the Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), which is currently under development by an international collaboration and is planned to be launched in 2023. We focus on the EMI from (a) the low-frequency magnetic field generated by the magnetic torquers (MTQ) used for the spacecraft attitude control and (b) the radio-frequency (RF) electromagnetic field generated by